Unopened containers of microcuvettes may be used until the expiration date listed on bottle. Hemocue glucose 201 rt system hemocue glucose 201 rt system measures glucose levels with a portable and batteryoperated system with room temperature microcuvette storage. Glucose test hemocue glucose 201 rt system hemocue. At normal hematocrit values plasma glucose is 1015% higher than whole blood glucose. The hemocue glucose 201 dm system was reported to have presented a single low measurement result that was compared to a laboratory result. Ce marked results only use adapters recommended by hemocue, see on page 44.
Note, microcuvettes stored in a freezer must be allowed to reach room temperature approx. Blood glucose test hemocue glucose 201 rt system hemocue. Hemocue hb 201 method and sample collection method iecbe. Use the hemocue glucose 201 microcuvettes prior to their expiry the hemocue glucose 201 analyzer is only to be used with date. Hemocue hb 201 microcuvettes microcuvettes are stored at room temperature away from any direct heat source. For alternative cleaning of hemocue bhemoglobin photometer produced earlier than july 1992, please contact your local hemocue distributor.
Aid in the diagnosis and monitoring of diabetes with confidence as you get lab quality results at the point of care with the hemocue glucose 201 system. Jul 28, 2017 i couldnt find a regulatory reason, but we require qc run every 24 hrs on the hemocue hb 201. Microcuvette technology means no need to bring analyzer near patients, reducing the risk of spreading infection. Method agreement was evaluated by linear regression. In fact, the results are so accurate theyre used for screening and diagnosing diabetes mellitus and gestational diabetes, and have been used in validations as reference for other methods. Hemocue america glucose 201 analyzer glucose 201 analyzer. Hemocue glucose systems are handheld spectrophotometers, developed for professional use, that deliver labaccurate results.
A newly developed system, hemocue glucose 201rt, has microcuvettes that can be stored at room temperature. Many laboratory methods measure the glucose concentration in plasma. Evaluation of the hemocue glucose 201 roomtemperature. Hemocue hb 201 method and sample collection v2 appn. Background the professionaluse systems hemocue glucose 201. Plus, you have the added controls and productivity means made possible with advanced data management. Ad0900200au 9vac 200ma power supply cord cable charger mains psu.
By means of a wide range of settings and definable options, the systems can be made to prompt the operator for identification, batch numbers, quality control and other required. Hemocue glucose 201 community, manuals and specifications. Hemocue america glucose 201 dm analyzer bring modern data management capabilities to the hemocue product line. Kob hemoglobinanalyse, hemocue til professionelle abbott. Hemocue glucose 201 dm rt system portable and batteryoperated system with room temperature microcuvette storage with its unique cuvette technology, the hemocue glucose 201 dm rt system gives you the highest accuracy at the point of care while reducing the risk of spreading infection. This procedure describes the different steps to obtain the result. There is no international accepted reference method for the determination of glucose. Manufacturer narrative hemocue glucose 201 dm measured 3. Hemocue america glucose 201 dm analyzer hb 201 dm analyzer. With its unique cuvette technology, the hemocue glucose 201 dm rt system gives you the highest accuracy at the point of care. With its unique microcuvette technology, the hemocue glucose 201 dm rt system gives you the highest accuracy at the point of care while reducing the risk of spreading infection. Nov 24, 2015 hemocue glucose 201 microcuvetes special notice. Store unopened hemocue glucose 201 microcuvettes below 8 c 46 f incl.
This test is performed every second hour if the analyzer is left turned on. Hemocue glucose 201 microcuvettes 110706 from 4md medical. Accuracy of a simplified glucose measurement devicethe. Hemocue america glucose 201 dm analyzer hb 201 dm analyzer healthcare. The calibration of the analyser has been changed 1. Hemocue glucose 201 system allows you to accurately measure blood glucose levels to aid in the diagnosis and monitoring of diabetes. Not only does the unique cuvette technology enable accuracy in just three simple steps, but it also a workflow that reduces contamination risks. The hemocue glucose 201 analyzer is available with data management capabilities. Evaluation of the hemocue glucose 201 room temperature. The hemocue glucose systems measure the glucose concentration in whole blood.
The hemocue 201 dm rt systems for glucose with data management functions allow healthcare providers to ensure the authorized and appropriate use of the analyzers. Not only does the unique cuvette technology enable high accuracy in just three simple steps, with a workflow that reduces contamination risks. Other than good laboratory practice, the ed felt it would better to have the staff run the controls at the same time as they do the glucose meter controls. Glucose test hemocue glucose 201 system faq hemocue. The hemocue glucose 201 analyzer is a handheld instrument and reports plasma equivalent values. The hemocue glucose 201 system combines the precision and accuracy of a laboratory measurement with a quick turn around time and easeofuse. Used hemocue glucose 201 dm rt glucose analyzer for sale. Hemocue glucose 201 rt system measures glucose levels with a portable and batteryoperated system with room temperature microcuvette storage. Follow the directions in the hemocue cleaner instructions for use. Hemocue b4 received a complaint on hemocue glucose 201 dm from hemocue b6. Hemocue glucose 201 microcuvettes hemocue glucose 201 microcuvettes are for in vitro diagnostic use only. Hemocue america glucose 201 analyzer small, handheld dedicated instrument that is based on the glucose dehydrogenase method manufacturer. Mar 30, 2016 hemocue shop and purchase your hemocue testing equipment and supplies by clicking on the link above.
Instrument maintenance and quality controls must be performed monthly prior to patient testing. Lab accurate glucose test diabetes diagnosis hemocue. Shop and purchase your hemocue testing equipment and supplies by clicking on the link above. Turn the analyzer off and remove the cuvette holder as described in the operating manual 2. Evaluation of the relationship between capillary and venous. Learn vocabulary, terms, and more with flashcards, games, and other study tools. Venous specimens in edta vacutainer tubes, n 152, were analyzed in duplicate by each of the 3 methods to determine method reproducibility and precision using patient specimens. Portable and batteryoperated system with room temperature microcuvette storage and data management, ideal for glucose testing in mobile settings. The hemocue glucose 201 dm rt system is used for quantitative determination of glucose in whole blood, supplementing the clinical evidence in the diagnosis and treatment of patients with diabetes as well as monitoring of neonatal blood glucose levels.
Hemucue glucose 201 dm rt portable blood glucoselevel measuring instrument hemucue glucose 201 dm rt. Three simple steps 1 2 3 gpm319int 709 hemocue has been a leader in pointofcare medical diagnostics for over 30 years. Hemocue hb 201 dm testing is considered a waived test according to the fda 5. The hemocue glucose 201 system puts labequivalent answers in health professionals hands when theyre needed most at the point of care. Every time the analyzer is turned on, it will automatically verify the performance of the optical unit of the analyzer. The individually packaged microcuvettes can be stored at room temperature for up to 3 days. The controls are beyond their expiration dates or have been improperly stored 8.